BANGKOK — 27 November 2026, Bangchak’s preliminary findings on the Phra Khanong refinery fire show a heat exchanger in the Hydrocracking Unit ruptured. All production units were shut down for safety, and experts are urgently investigating the cause and assessing damage. Seven injured remain hospitalized, and air quality within a 5 km radius is confirmed to be normal.
Bangchak Corporation Public Company Limited has issued an update on the fire at its Bangchak Phra Khanong refinery. The company sincerely apologized for the incident on 26 November 2026 and said it immediately shut down all production units after the fire, putting safety first.
Preliminary inspection found that a heat exchanger at the Hydrocracking Unit ruptured. Experts are currently investigating the sequence of events and the root cause, as well as assessing the damage to the equipment. The company continues to control the incident area and restrict access because the production process involves chemicals and is complex.
Bangchak purged residual gas from the system to international standards, which may periodically produce steam-like plumes. Air quality is monitored in real time, around the clock, within a 5 km radius of the refinery.
Latest readings at 07:00 on 27 November 2026 show air quality around the refinery within normal levels, consistent with the Pollution Control Department’s 08:00 measurements.
Seven people remain hospitalized: 1 employee and 6 contractors. Two others have been reported with minor injuries and have since been able to return home. Bangchak has stated that they will care for those injured in full, monitor their condition, coordinate closely with their families, and provide fair compensation. Updates will follow.